تخطي للذهاب إلى المحتوى

Fluke True RMS AC Clamp Meter 600A AC - 600 V AC/DC

https://www.egtrade.me/web/image/product.template/45284/image_1920?unique=2bbdc5b
(تقييم 0)
  • Small body and jaws fit perfectly in your hand and into
    tight places
  • Handy 'Display Hold' button keeps measurements on the
    display
  • Meter controls are positioned so current measurements can be
    done with one hand (index finger on clamp opening lever and
    thumb on rotary switch)
  • Large, backlit display (on most models) is easy-to-see
  • In-rush current function (on most models) for measuring starting
    current for motors, lighting, etc.
  • Auto shut-off maximizes battery life so the meter works when
    you need it
  • Improved low current measurement accuracy from new
    microprocessor technology
  • Five different models to meet your exact needs

Specifications
Voltage DC
Range:0 - 600.0 V
Accuracy:1% +/-5 counts
Voltage AC
Fluke 333/334
Range:0 - 600.0 V
Accuracy:1% +/-5 counts (50/60 Hz)
AC Response:Averaging
Fluke 335
Range:0 - 600.0 V
Accuracy:1% +/-5 counts (50/60 Hz)
AC Response:True-rms
Fluke 336/337
Range:0 - 600.0 V
Accuracy:1% +/-5 counts (20-100 Hz),
6% +/-5 counts (100-400 Hz)
AC Response:True-rms
Current DC
Fluke 336
Range:0 - 600.0 A
Accuracy:2% +/-3 counts
Fluke 337
Range:0 - 999.9 A
Accuracy:2% +/-3 counts
Current AC
Fluke 333/334
Range:0 - 400.0 A
Accuracy:2% +/-5 counts (50/60 Hz)
AC Response:Averaging
Fluke 335
Range:0 - 600.0 A
Accuracy:2% +/-5 counts (50/60 Hz)
Crest Factor(50/60 Hz):2.4 @ 500A, 2.0 @ 600A,
add 2% for CF>2
AC Response:True-rms
Fluke 336
Range:0 - 600.0 A
Accuracy:2% +/-5 counts
(10-100 Hz),
6% +/-5 counts
(100 - 400 Hz)
Crest Factor(50/60 Hz):3 @ 500A, 2.5 @ 600A,
add 2% for CF>2
AC Response:True-rms
Fluke 337
Range:0 - 999.9 A
Accuracy:2% +/-5 counts (10-100 Hz),
6% +/-5 counts (100 - 400 Hz)
Crest Factor(50/60 Hz):3 @ 500A, 2.5 @ 600A,
1.42@1000 A, add 2%
for CF>2
AC Response:True-rms
Resistance
Fluke 333
Range:0 - 600.0 Ohm
Accuracy:1.5% +/-5 counts
Fluke 334/335/336/337
Range:0 - 600.0 Ohm,
6001 - 6000 Ohm
Accuracy:1.5% +/-5 counts
Frequency
Fluke 337
Range:5 - 400Hz
Accuracy:0.5% +/-5 counts
Trigger Level:10-100 Hz >= 5A, 5-10 Hz,
100-400 Hz >=10A
Inrush Current
Fluke 334/335/336/337
Integration Time:100 ms
Continuity
<= 30 Ohm
MIN/MAX
Fluke 337 only

Environmental Specifications
Operating temperature
-10 Deg C to +50 Deg C,
-14 Deg F to 122 Deg F
Storage temperature
-40 Deg C to +60 Deg C,
-22 Deg F to 140 Deg F
Operating Altitude
2,500 meters max,
6,500 ft max
Temperature
De-rating
Add 0.1 x specified accuracy
for each Deg C
above 28 Deg C or
below 18 Deg C
(above 82.4 Deg F or
below 64.4 Deg F)

Safety Specifications
Safety Rating
IEC 1010-2-032, 600V CAT III

Mechanical & General Specifications
Size
Fluke 333/334/335
240mm x 80mm x 40mm (9.375" x 3.125" x 1.625")
-
Fluke 336/337
250mm x 80mm x 40mm (9.875" x 3.125" x 1.625")
Weight
310 g (11oz)
Warranty
Three years
Battery life
Alkaline approximately 150 hours continuous
Automatic low battery indicator
Backlight
Fluke 334/335/336/337
Display Hold
Yes

0.00 LE 0.0 EGP 0.00 LE شامل الضريبة

0.00 LE شامل الضريبة

اتصل بنا

  • الماركة

هذه التركيبة غير موجودة.

 طرق دفع عند الاستلام متعددة​

 ارجاع مجانى لمدة 14 يوم

 توصيل سريع​

 ضمان اقل سعر

طرق الدفع: يتوفر العديد من طرق الدفع 

المستندات

الشروط والأحكام
تماشيًا مع إرشادات الشحن الخاصة بنا، تتطلب الغالبية العظمى من المنتجات في متجرنا عادةً 24 ساعة عمل لمعالجة الطلبات والتحضير للشحن. بعض المنتجات ذات خصائص فريدة قد تحتاج إلى بروتوكولات تخزين أو إنتاج محددة، مما قد يجعلها غير متاحة في وقت تنفيذ الطلب او تحتاج الى فترات اضافيه للانتاج.
 يرجى الاطلاع أيضًا على:
مراجعة الطلبات     الشحن والتوصيل 
المرتجعات     سياسة الضمان 
طرق الدفع 


مرجع داخلي: 335

المواصفات

الماركة فلوك

Customers Also view

Check out what other customers are care about !

Your Dynamic Snippet will be displayed here... This message is displayed because you did not provide both a filter and a template to use.

Featured Products

Check out what's new in our products !

Your Dynamic Snippet will be displayed here... This message is displayed because you did not provide both a filter and a template to use.

Subscribe to our newsletter

Get all the latest news, blog posts and product updates from our company, delivered directly to your inbox.

Thanks for registering!